Optični kabel I-v(zn)hh duplex kabel

Optični kabel I-v(zn)hh duplex kabel

DUPLEX CABLE, FIGURE-0, METAL-FREE, HALOGEN-FREE, FLAME RETARDANT Suitable for assembly into a duplex connection cable between passive and active network components indoors, designed as “figure 0" PRODUCT SUITABILITY:Fiber optic cable Sheath color:yellow (E9) orange (G50, G62.5) turquoise (G50 OM3) Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter compressive strength (crush):1000 N/10 cm impact:5 Nm static:15 x cable-diameter dynamic:20 x cable-diameter storage and transport:0°C up to +50°C installation:0°C up to +50°C operation:0°C up to +50°C
Optični Kabel A-dq(zn)2y (hd) Ø 3,9 Mm

Optični Kabel A-dq(zn)2y (hd) Ø 3,9 Mm

CENTER UNITUBE CONSTRUCTION, METAL-FREE, LONGITUDINALLY WATERTIGHT Suited for outdoor use - for Metro, Access or FTTx implementations and and for blowing in into mini pipe systems FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter tube diameter mm:3,0 number of tubes:1 max. fibers / tube:24 max. number of fibers:24 tensile strength approx. N:400 weight approx. kg/km:13,0 outer diameter approx. mm:3,9 compressive strength (crush):1000 N/10 cm impact:1 Nm (3 impacts, 300 mm hammer radius) torsion:5 cycles ±360° kink, tube:The tube do not kink min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-30°C up to +70°C installation:-5°C up to +50°C operation:-20°C up to +70°C water penetration:No water on free end
Železniški kabel Optični kabel A-dq(zn)(l)2yrg2y

Železniški kabel Optični kabel A-dq(zn)(l)2yrg2y

RAILFOOT CABLE, LOOSE TUBE CONSTRUCTION, METAL-FREE, WATERTIGHT, RODENT PROTECTION, ALUMINIUM-PE-COMPOSITE-LAYER SHEATH, STEEL WIRE ARMOURING The fiber-optic railfoot cable is designed for use in telecommunication systems. It can be laid directly on the rail foot or other areas subjected to vibrations and impacts, but is also suitable for fixed laying in cable ducts, conduits or direct burial. FILLING:dry filling / swellable materials OVERALL SHIELD, REINFORCEMENT:composite layer (L) round steel wires PRODUCT SUITABILITY:Railway cable fiber optic cable Fiber colors:red, green, blue, yellow Tube colors:first tube red, other tubes yellow Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter tube diameter mm:2,0 number of tubes:6 max. fibers / tube:4 max. number of fibers:24 tensile strength approx. N:3.500 weight approx. kg/km:310 outer diameter approx. mm:15,6 tensile strength:see above table specification:DB TL 416.0510 compressive strength (crush):3000 N/10 cm impact:25 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times water penetration:No water on free end
Kombinacijski Kabel A-dsf(zn)(l)2y + 1x2x0,6

Kombinacijski Kabel A-dsf(zn)(l)2y + 1x2x0,6

LOOSE TUBE CONSTRUCTION, JELLY FILLED CABLE CORE, WATERTIGHT, RODENT PROTECTION, ALUMINIUM-PE-COMPOSITE-LAYER SHEATH Suited for outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:petrol jelly OVERALL SHIELD, REINFORCEMENT:composite layer (L) PRODUCT SUITABILITY:Combination cable Standardbedruckung:PENGG CABLE - Cable type - Fiber number / type - ID number - Meter Crush resistance:3000 N/10 cm Impact resistance:25 Nm Torsion:5 cycles ± 360 ° Kabelknick:The cable does not kink if the cable loop is 12 times the cable diameter. Minimum bending radius:R = 20 x D (outer cable diameter) Storage and transport:-40 ° C to + 70 ° C Installation:-5 ° C to + 60 ° C Operation:-25 ° C to + 70 ° C Water ingress:No water at the free end
Optični kabel A/i-dqh(bn)h

Optični kabel A/i-dqh(bn)h

LOOSE TUBE CONSTRUCTION, LONGITUDINALLY WATERTIGHT, SLIGHT RODENT PROTECTION, HALOGEN-FREE, FLAME RETARDANT Suited for indoor and outdoor use - for fixed laying in cable ducts, conduits or direct burial FILLING:dry filling / swellable materials PRODUCT SUITABILITY:Fiber optic cable Application:FRP central element Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – CPR class CE-marking – meter compressive strength (crush):3000 N/10 cm impact:25 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation: -5°C up to +60°C operation:-30°C up to +70°C water penetration:No water on free end
Telekomunikacijski kabel M-bakreni kabel ..x2x0,6

Telekomunikacijski kabel M-bakreni kabel ..x2x0,6

FOAM-SKIN-PE INSULATED, QUAD TWISTED, JELLY FILLED TELECOMMUNICATION CABLE Cable for outdoor application designed for high frequency XDSL-connections for blowing technique FILLING:petrol jelly OVERALL SHIELD, REINFORCEMENT:unshielded PRODUCT SUITABILITY:Telecommunication cable ladder:solid, bare copper wire Ø 0.6 mm Insulating sleeve:Foam skin PE Verseilung:Four cores each stranded to form star fours, star quads to form a cable core, a drain wire filling:Cable core filled with petrolatum, wrapped with plastic tape Mantel:PE, orange Moisture barrier:0.15 mm aluminum tape with polyethylene (0.05 mm) coated on both sides Conductor diameter:0,6 mm Conductor resistance:≤66 Ω / km Change in resistance:≤2 % Insulation resistance:≥5 GΩkm Operating capacity:≤55 nF / km Propagation speed (1MHz):≤60 % Ader / Ader:700 Veff/50Hz/1min Characteristic impedance (1-60 MHz):110 ±15% Ω
Telekomunikacijski Kabel U-72 Mp-h 1x2x0,5 Bd/st

Telekomunikacijski Kabel U-72 Mp-h 1x2x0,5 Bd/st

HALOGENFREE SWITCHBOARD CABLE FOR IHC-SYSTEMS The cable is used for data transmission in indoor areas FILLING:unfilled OVERALL SHIELD, REINFORCEMENT:foil PRODUCT SUITABILITY:Telecommunication cable ladder:solid, bare copper wire Ø 0.5 mm Insulating sleeve:ON Aderfarben:WS/BL Verseilung:two cores to pair Contribution:tinned copper wire Ø 0.5 mm umbrella:aluminum-laminated plastic film, tear cord Mantel:FRNC jacket, gray Type construction:1x2x0,5 Material number:5132391 Outside diameter approx. Mm:3,8 Weight approx kg / km:15,7 Conductor diameter:0,5 mm Conductor resistance:≤97,8 Ω / km Resistance difference:≤2 % Insulation resistance:≥2 GΩkm Ader / Ader:2000 V / AC 1min
Optični Kabel A-d2y(zn)2y (hd) Adss 4kn

Optični Kabel A-d2y(zn)2y (hd) Adss 4kn

LOOSE TUBE CONSTRUCTION, METAL-FREE ADSS (all-dielectric-self-supporting) cable are metal-free air hanging cable, suited for fixing on poles. The pole distance is at 4 kN maximum 60 m. FILLING:unfilled PRODUCT SUITABILITY:Fiber optic cable Application:FRP central element Fiber / tube colors:PENGG KABEL standard according to “Color codes – Fiber optic cables” in the document Standard marking:PENGG KABEL – cable type – fiber count/type – ID number – meter compressive strength (crush):3000 N/10 cm impact:25 Nm torsion:5 cycles ±360° kink, cable:The cable do not form a kink when a loop is drawn together to a diameter 12 times min. bending radius:R = 20 x D (cable outer diameter) storage and transport:-40°C up to +70°C installation:-5°C up to +60°C operation:-30°C up to +70°C span distance:up to 60 m
Telekomunikacijski kabel F-2yc2y ..x2x0,8

Telekomunikacijski kabel F-2yc2y ..x2x0,8

PE-INSULATED, LOCAL TELECOMMUNICATION CABLE WITH COPPER SHIELD In all kinds of operating premises (excepted locations with special protection demands - like in fire or highly combustible premises); e.g. for local area networks of the telecom, as station communication cables and for small telephone networks of industry, traffic and public utilities. FILLING:unfilled OVERALL SHIELD, REINFORCEMENT:copper braid or tape PRODUCT SUITABILITY:Telecommunication cable ladder:solid, bare copper wire Ø 0.8 mm Insulating sleeve:PE ( 2Y ) Verseilung:four cores to star fours each; Star quads stranded in layers to form a cable core umbrella:Wrapping with copper tape ( C ) Mantel:PE, black ( 2Y ) laying:Suitable for laying in earth, water, cable ducts, pipelines, etc. imprint:<Telephone receiver> <meter> Regulation:TLB X5019 (03.67) Conductor diameter:0,8 mm Loop resistance:≤73,2 Ω / km Insulation resistance:≥10 GΩkm Operating capacity (at f = 800Hz):≤55 nF / km Operating voltage:200 VAC Ader / Ader:500 V / 50Hz Core / screen:2000 V / 50Hz laying:-20 to +50 °C business:up to +70 °C