Izdelki za merilnik navora (5)

MERILCI REAKCIJSKEGA MOMENTA (VISOKE KAPACITETE) - Pretvorniki momenta

MERILCI REAKCIJSKEGA MOMENTA (VISOKE KAPACITETE) - Pretvorniki momenta

Universal nonrotating torque meters combining accuracy and sturdiness. o Easy to install, compact design Also available as standard reference torque meters Reference:6100-6105 Protection class:IP65 Material:stainless steel (6100), nickel-plated steel (6105) Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):± 1 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):200 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

Nonrotating torque meters with hexagonal head. Cable output with radial connector (see drawing) Mechanical fastening by collar (see drawing) Reference:6500B Wide range of capacities:from 2 to 1000 N·m Protection class:IP54 Material:stainless steel Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10 Zero shift after loading (% F.S.*):<± 0.025
MERILCI REAKCIJSKEGA MOMENTA ZA RATCHET KLJUČE - Pretvorniki momenta

MERILCI REAKCIJSKEGA MOMENTA ZA RATCHET KLJUČE - Pretvorniki momenta

Nonrotating torque meters designed to be placed between ratchet and wrench. Easy to install (standardised wrenches) o Compact design Reference:6305 Protection class:IP54 Material:alloy steel Cable length:3 m (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-25...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3 Static lateral force limit (% F.S.*):10
MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

Universal nonrotating torque meters combining accuracy and sturdiness. Easy to install, compact design Also available as standard reference torque meters Reference:6200-6205 Protection class:see drawing table (IP) Materials:stainless steel (6200), nickel-plated steel (6205) Cable length:3 m (other lengths available on request) Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Zero shift after loading (% F.S.*):<± 0.025 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):<± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350 ± 2 Output resistance (ohm(s)):350 ± 2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):130 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):50 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):<± 0.3
MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

MERILCI REAKCIJSKEGA MOMENTA - Pretvorniki momenta

Nonrotating torque meters with hexagonal head. Compact design, easy to install Material stainless steel (6500 / 6500A) anodised aluminium alloy (6502 / 6502A) Reference:6500-6502 6500A-6502A 6500-6502:cable output with radial cable gland 6500A-6502A:cable output with axial cable gland 6500(A)-6502(A):mechanical fastening with threaded holes (see drawing) Protection class:IP54 Cable length:see drawing table - CL (other lengths available on request) Combined error (non-linearity + hysteresis) (% F.S.*):<± 0.25 Repeatability error (% F.S.*):<± 0.1 Creep error over 30 min. (% F.S.*):<± 0.1 Reference temperature (°C):23 Compensated temperature range (°C):-10...+45 Service temperature range (°C):-30...+70 Storage temperature range (°C):-50...+85 Temperature coefficient of the sensitivity (% F.S.*/10°C):< ± 0.05 Temperature coefficient of zero signal (% F.S.*/10°C):<± 0.035 Nominal sensitivity (mV/V):1.5 Input resistance (ohm(s)):350±2 Output resistance (ohm(s)):350±2 Insulation resistance (50 V) (Mohm(s)):> 5000 Reference excitation voltage (VDC):10 Permissible nominal range of excitation voltage (VDC):3...12 Safe load limit (% F.S.*):120 Breaking load (% F.S.*):> 300 Permissible dynamic loading (% F.S.*):40 Zero balance (mV/V):± 0.02 Sensitivity tolerance (%):< ± 0.3 Static lateral force limit (% F.S.*):10